图片
自定模版
图片
设为首页加入收藏
 
产品详情
FH-WFSDA全自动防火阀
FH - WFSDA automatic fire damper
Performance:
Normally open,the control center will signal actuator when fire
happen,then electromagnet energized and act,damper close and signal.
2.DC motor will reset the damper(automatic) after acting.
3.The damper start and reset manually.
4.Fuse will act and the damper close automatically when the air temperature in duct reach 70℃(or 280℃).
5.action signals or reset signals feed back to control center and actuate interlocks.
Technical data:
action temperature of fuse:70℃
Leakage(delta P 300Pa):<=500m³/㎡h
Drag coefficient in full open:<0.5
Fire resistance rating:1.5h
Control voltage:DC24V
Action current:0.2A
Action time:instantaneous
Reset current:0.3 A(automatic)
Reset time:<=12s(automatic)

 

 

 

FH-WFSDA全自动防火阀

性能:

1平时呈常开状态,火灾时烟感器通过控制中心发来电信号(DC24V),执行机构的电磁铁通电动作,阀门自动关闭并输出关闭电信号。

2(全自动)阀门动作后直流电机驱动复位。

3阀门可手动启动,手动复位。

4当温度升到70℃(或280℃)熔断器动作,门自动关闭。

5当动作信号或复位信号反馈到控制中心及起动联锁设备

 

主要技术参数:     

1熔断器动作温度:70℃

2漏风量(压差300Pa):≤500m³/h

3全开时阻力系数:<0.5

4阀门耐火等级:1.5h

5控制电压:DC24V

6动作电流:0.2A

7动作时间:瞬时

8复位电流:0.3A(全自动)

9复位时间:≤12S(全自动)

图片
脚注信息
版权所有 Copyright(C)2009-2012 伦登风机(天津)有限公司
津ICP备11002471号 技术支持:易成网络 
图片
访问统计